Honeywell Midas®-M Fixed Gas Detector
- Over 33 gases available with 2-year warranty: 17 gases available at launch
- 4-in-1 multi smart sensor cartridge with onboard ‘e-calibration’ certificate
- Modular design for easy to use and service (front, pump, sensor cartridge, main and base)
- 3 built-in relays (Form C) for Alarms 1, 2 and Fault
- Power over Ethernet (PoE) communication
Quantity: | Unit Price ($) |
1+ | Contact Us |
Product description
The Honeywell Midas®-M Gas Detector is a fixed extractive, 4-in-1 multi-gas detector. The Midas®-M can detect more than 30 gases – precisely, easily and quickly, drawing a sample locally or from a remote point to a sensor cartridge that is located inside the detector’s chassis. A wide range of toxic, flammable and oxygen gas sensor cartridges are available that enable the detection of gases used or generated in the Semiconductor and other manufacturing industries.
Key Features and Benefits:
▪ Keypad interface and remote web browser interface
▪ Factory-calibrated sensors to reduce the need for frequent gas testing
▪ Isolated 0-21 mA analogue output with fault and event reporting
▪ Modbus/TCP Ethernet for easy connectivity to all control and alarm systems ports for control connectivity and service interaction
▪ Robust extractive pump system (2-year lifetime) sampling up to 100 feet
▪ Fixed extractive, 4-in-1 multi-gas detector.
▪ Flow Rate: 500 mL/min
▪ Transport Time: 2 to 30 seconds maximum
▪ Sample Line Tubing: 0.125 in ID x 0.25 in OD
Part Number | Description |
---|---|
Extractive Transmitter for Universal Gas Detection | |
MMT-01 | Midas-M 4-20mA and TCPIP Modbus Transmitter |
MMT-T01 | Midas-M 4-20mA and TCPIP Modbus Transmitter w/Tube |
MMT-B01 | Midas-M 4-20mA and TCPIP Modbus Transmitter Bulk (6) |
MMT-02 | Midas-M TCPIP Modbus Transmitter |
MMT-T02 | Midas-M TCPIP Modbus Transmitter w/Tube |
MMT-B02 | Midas-M TCPIP Modbus Transmitter Bulk (6) |
Extractive Transmitter with LIT | |
MMT-L01 | Midas-M 4-20mA and TCPIP ModbusTransmitter – LIT |
MMT-LT01 | Midas-M 4-20mA and TCPIP Modbus Transmitter – LIT |
MMT-LB01 | Midas-M 4-20mA and TCPIP Modbus Transmitter w/Tube – LIT |
MMT-L02 | Midas-M TCPIP Modbus TransmitterTube – LIT |
MMT-LT02 | Midas-M TPCIP Modbus Transmitter Bulk (6) – LIT |
MMT-LB02 | Midas-M TCPIP Modbus Transmtr, (6)Bulk – LIT |
Midas-M Sensor List – Build a complete cartridge using chart below | |
MMC | *MMC will require a 1 cent charge to customer PO and Invoicing to match |
MMS-00 | Midas-M Dummy Sensor |
MMS-E2 | Midas-M HCI/0-8ppm,2yrs |
MMS-X2 | Midas-M Silane (SiH4) 0 -20 ppm, 2 years |
MMS-G2 | Midas-M H2/0-1000ppm,2yrs |
MMS-L2 | Midas-M Chlorine (CI2) 0 – 2ppm, 2 years |
MMS-A2 | Midas-M NH3/0-100ppm,2yrs |
MMS-C2 | Midas-M CO/0-100ppm,2yr |
MMS-R2 | Midas-M PH3/0-1200ppb,2yrs |
MMS-U2 | Midas-M Ozone (O3) 0 – 0.4ppm, 2 years |
MMS-D2 | Midas-M Oxygen (O2) 0 – 25%v/v, 3 years |
MMS-S2 | Midas-M SO2/0-8ppm,2yrs |
MMS-Z2 | Midas-M HF/0-12ppm,2yrs |
MMS-ET | Midas-M EthyleneOxide_ETO 0-40ppm,2yrs |
MMS-VN | Midas-M NitrogenDioxide_NO2 0-12ppm,2yrs |
MMS-H4 | Midas-M HydrogenSulfide_H2S 0-40ppm,2yrs |
Mounting Accessories | |
MM-REL | |
MVIP3632-2A | 2A 24VDC power supply in vented NEMA 4 enclosure |
MVIP3632-5A | 5A 24VDC power supply in vented NEMA 4 enclosure |
Duct Sampling Adaptors | |
1283K1090 | Duct Adapter for 1/4″ O.D. tubing for 4-16″ round ducts |
0235-0095 | Union Fitting 1/4″ tube, polypropylene |
Service Items | |
MM-PM | Midas-M Pump Module |
MM-FIL | Midas-M Filter Module |
MM-FRT | Midas-M Front Module |
MM-B01 | Midas-M 4-20mA Base Module |
MM-B02 | Midas-M Modbus TCP Base Module |
MM-M01 | Midas-M 4-20mA Main Module |
MM-M02 | Midas-M Modbus TCP Main Module |
MM-CAT | Midas-M Cartridge w/o Smart Cells |
MM-LPM | Midas-M Pump Module – LIT |
MM-LIT | Midas-M Check Valve – LIT |
Tubing and External Sample Line Filters | |
780248 | |
1991-0147 | End of Line Particulate Filter for Corrosive Gases, Disposable This disposable filter provides protection against particulate build up in the sample line when monitoring for Corrosive Gases. |
0235-0095 | Union Fitting – Use to connect disposable filter to end of line |
1830-0055 | End of Line Particulate Filter for Corrosive Gases, ReusableThis reusable filter housing provides protection against particulate build up in the sample line when monitoring for Corrosive Gases. Replaceable filter element (P/N 0235-1072) purchased separately |
0235-1072 | Replacement “Corrosive” Filter Elements (pk 100) For |
102599 | Tubing Teflon® FEP 1/4″ OD x 1/8″ ID (Sample inlet) (Price per Foot) |
1991-0136 | Tubing Teflon® FEP 1/4″ OD x 1/8″ ID (Sample Inlet) (100′ continuous length) |
100440 | Tubing Polypropylene 1/4″ OD X 3/16″ ID (Exhaust) (Price per Foot) |
1991-0137 | Tubing Polypropylene 1/4″ OD X 3/16″ ID (Exhaust) (100′ continuous length) |
Honeywell Midas®-M Fixed Gas Detector
- Over 33 gases available with 2-year warranty: 17 gases available at launch
- 4-in-1 multi smart sensor cartridge with onboard ‘e-calibration’ certificate
- Modular design for easy to use and service (front, pump, sensor cartridge, main and base)
- 3 built-in relays (Form C) for Alarms 1, 2 and Fault
- Power over Ethernet (PoE) communication
Quantity: | Unit Price ($) |
1+ | Contact Us |
Quantity | Unit Price ($) |
1+ | Contact |
Product description
The Honeywell Midas®-M Gas Detector is a fixed extractive, 4-in-1 multi-gas detector. The Midas®-M can detect more than 30 gases – precisely, easily and quickly, drawing a sample locally or from a remote point to a sensor cartridge that is located inside the detector’s chassis. A wide range of toxic, flammable and oxygen gas sensor cartridges are available that enable the detection of gases used or generated in the Semiconductor and other manufacturing industries.
Key Features and Benefits:
▪ Keypad interface and remote web browser interface
▪ Factory-calibrated sensors to reduce the need for frequent gas testing
▪ Isolated 0-21 mA analogue output with fault and event reporting
▪ Modbus/TCP Ethernet for easy connectivity to all control and alarm systems ports for control connectivity and service interaction
▪ Robust extractive pump system (2-year lifetime) sampling up to 100 feet
▪ Fixed extractive, 4-in-1 multi-gas detector.
▪ Flow Rate: 500 mL/min
▪ Transport Time: 2 to 30 seconds maximum
▪ Sample Line Tubing: 0.125 in ID x 0.25 in OD
Part Number | Description |
---|---|
Extractive Transmitter for Universal Gas Detection | |
MMT-01 | Midas-M 4-20mA and TCPIP Modbus Transmitter |
MMT-T01 | Midas-M 4-20mA and TCPIP Modbus Transmitter w/Tube |
MMT-B01 | Midas-M 4-20mA and TCPIP Modbus Transmitter Bulk (6) |
MMT-02 | Midas-M TCPIP Modbus Transmitter |
MMT-T02 | Midas-M TCPIP Modbus Transmitter w/Tube |
MMT-B02 | Midas-M TCPIP Modbus Transmitter Bulk (6) |
Extractive Transmitter with LIT | |
MMT-L01 | Midas-M 4-20mA and TCPIP ModbusTransmitter – LIT |
MMT-LT01 | Midas-M 4-20mA and TCPIP Modbus Transmitter – LIT |
MMT-LB01 | Midas-M 4-20mA and TCPIP Modbus Transmitter w/Tube – LIT |
MMT-L02 | Midas-M TCPIP Modbus TransmitterTube – LIT |
MMT-LT02 | Midas-M TPCIP Modbus Transmitter Bulk (6) – LIT |
MMT-LB02 | Midas-M TCPIP Modbus Transmtr, (6)Bulk – LIT |
Midas-M Sensor List – Build a complete cartridge using chart below | |
MMC | *MMC will require a 1 cent charge to customer PO and Invoicing to match |
MMS-00 | Midas-M Dummy Sensor |
MMS-E2 | Midas-M HCI/0-8ppm,2yrs |
MMS-X2 | Midas-M Silane (SiH4) 0 -20 ppm, 2 years |
MMS-G2 | Midas-M H2/0-1000ppm,2yrs |
MMS-L2 | Midas-M Chlorine (CI2) 0 – 2ppm, 2 years |
MMS-A2 | Midas-M NH3/0-100ppm,2yrs |
MMS-C2 | Midas-M CO/0-100ppm,2yr |
MMS-R2 | Midas-M PH3/0-1200ppb,2yrs |
MMS-U2 | Midas-M Ozone (O3) 0 – 0.4ppm, 2 years |
MMS-D2 | Midas-M Oxygen (O2) 0 – 25%v/v, 3 years |
MMS-S2 | Midas-M SO2/0-8ppm,2yrs |
MMS-Z2 | Midas-M HF/0-12ppm,2yrs |
MMS-ET | Midas-M EthyleneOxide_ETO 0-40ppm,2yrs |
MMS-VN | Midas-M NitrogenDioxide_NO2 0-12ppm,2yrs |
MMS-H4 | Midas-M HydrogenSulfide_H2S 0-40ppm,2yrs |
Mounting Accessories | |
MM-REL | |
MVIP3632-2A | 2A 24VDC power supply in vented NEMA 4 enclosure |
MVIP3632-5A | 5A 24VDC power supply in vented NEMA 4 enclosure |
Duct Sampling Adaptors | |
1283K1090 | Duct Adapter for 1/4″ O.D. tubing for 4-16″ round ducts |
0235-0095 | Union Fitting 1/4″ tube, polypropylene |
Service Items | |
MM-PM | Midas-M Pump Module |
MM-FIL | Midas-M Filter Module |
MM-FRT | Midas-M Front Module |
MM-B01 | Midas-M 4-20mA Base Module |
MM-B02 | Midas-M Modbus TCP Base Module |
MM-M01 | Midas-M 4-20mA Main Module |
MM-M02 | Midas-M Modbus TCP Main Module |
MM-CAT | Midas-M Cartridge w/o Smart Cells |
MM-LPM | Midas-M Pump Module – LIT |
MM-LIT | Midas-M Check Valve – LIT |
Tubing and External Sample Line Filters | |
780248 | |
1991-0147 | End of Line Particulate Filter for Corrosive Gases, Disposable This disposable filter provides protection against particulate build up in the sample line when monitoring for Corrosive Gases. |
0235-0095 | Union Fitting – Use to connect disposable filter to end of line |
1830-0055 | End of Line Particulate Filter for Corrosive Gases, ReusableThis reusable filter housing provides protection against particulate build up in the sample line when monitoring for Corrosive Gases. Replaceable filter element (P/N 0235-1072) purchased separately |
0235-1072 | Replacement “Corrosive” Filter Elements (pk 100) For |
102599 | Tubing Teflon® FEP 1/4″ OD x 1/8″ ID (Sample inlet) (Price per Foot) |
1991-0136 | Tubing Teflon® FEP 1/4″ OD x 1/8″ ID (Sample Inlet) (100′ continuous length) |
100440 | Tubing Polypropylene 1/4″ OD X 3/16″ ID (Exhaust) (Price per Foot) |
1991-0137 | Tubing Polypropylene 1/4″ OD X 3/16″ ID (Exhaust) (100′ continuous length) |