Honeywell FSL100 Series Flame Detectors
- UV, UV/IR and IR3 Flame Detectors to cover a wide range of applications
- Robust, simple to install & set up; Wide angle and fast speed of response
- Automatic test and test lamps for simple check and maintenance
Quantity: | Unit Price ($) |
1+ | Contact Us |
Product description
The Honeywell FSL100 Series Flame Detectors are Optoelectronic flame detectors for a wide range of Light Industrial fire detection from Honeywell Analytics.
Honeywell’s FSL100 range of Light Industrial/Commercial Flame Detectors enables simple coverage of fire hazard areas across many fire hazard applications. Installation, set-up and operation are simple. Wide solid area coverage and fast speed of response optimise safety. With inbuilt automatic test and test lamps available to cover all models, reliability is ensured.
A range of middle-market Optical Flame Detectors join the HA FSX High-End products. Addresses a wide range of fire protection applications both indoors and outdoors. With 3 versions to cover a wide range of flaming fires: Ultraviolet (UV), Ultraviolet/Infrared (UV/IR) and Triple Infrared (IR3).
Detecting a wide range of Hydrocarbon and Non-Hydrocarbon flaming fires means that many application areas can be addressed. Wide viewing angleOptical detection of radiant energy in a solid angle Field of View enables coverage of a large risk area. A simple optional mounting bracket allows the FSL100 to be installed and aligned covering the hazard. Fast responseFar faster than other technologies, by responding to flaming fires in seconds enabling a more rapid response to danger before the fire can escalate.
FM Class 1, 2 & 3 Div2 can be installed indoors or outdoors and in Hazardous areas typically looking into a Div 1 area from a distance.
FM 3260 performance certified to FM 3260 for flame Detector performance. Relay and current output (Fault and Alarm) Analog stepped output and Alarm/Fault relays for simple connectivity.
Inbuilt Automatic Test and Simple to use Test LampsFSL100 maintains continuous internal health monitoring. Test lamps enable simple operational and field-of-view testing.
Features & Benefits:
▪ UV, UV/IR and IR3 Flame Detectors to cover a wide range of applications
▪ Robust, simple to install & set up: Wide angle and fast speed of response
▪ Automatic test and test lamps for simple check and maintenance
Ease of Installation and Use:
▪ FSL100 Flame Detectors – UV, UV/IR and IR3 for light industrial applications
▪ GRP Housing, available in Red or White with optional swivel mount
▪ 12-14Vdc, 25mA nominal operation
▪ 4 to 20mA and Relay outputs
▪ Long range test lamp available
▪ High visibility red or discrete white models available
Great Performance:
▪ Approved to EN54-10 and FM3260 flame detector standards
▪ Comprehensive automatic self test
▪ Remote manual self test option
Fast & Reliable:
▪ High speed sensors and microprocessor
▪ Sophisticated analysis algorithms
▪ Continuous health monitoring
▪ False alarm rejection
Reduced Life Cost:
▪ Long life elements
▪ Pressure compensation to avoid contamination
▪ 2 year warranty
▪ Buy with confidence
Product Specification
General | |
---|---|
FSL100 Flame Detector types | FSL100-UV, FSL100-UVIR and FSL100-IR3; Choice of red or white housings |
Range | 110 ft /35 m (IR3), 25 m/80 ft (UV, UV/IR) alarming within 10 seconds to a 1 ft2(0.1 m2 )n-heptane fire |
Cone of vision | 90˚minimum horizontal and vertical |
Power | 10-28 VDC (12-24 VDC nominal) |
Local LEDs | – Continuous green: normal operation – Continuous yellow: fault – Flashing yellow: Fault and guide to repeat self-test after a self-test failure – Continuous red: alarm |
Current output | Standard available 4–20 mA (stepped, sinking, non-isolated): – 0 mA power fault / microprocessor fault – 2 mA optical fault – 4 mA normal operation – >20 mA alarm |
Relay output: – Alarm relay – Fault relay |
De-energized during normal operation, no alarm, SPDT, 30 VDC – 2 A, 60 W max. Energised during normal operation, no fault, SPDT, 30 VDC – 2 A, 60 W max. |
Cable gland & terminals | Cable entry M20 clearance. Supplied with gland suitable for cable diameter from 0.2” (5.5mm) to 0.5”(13mm). Terminals suitable for 0.5mm2 (20AWG) to 1.5mm2 (15AWG) wire |
Start up times | |
Alarm response time | 8 to 30 sec |
Alarm output settings | Selectable LEDs and relays latching/non-latching; factory setting: latching |
Automatic & manual Self-Test | Automatic Sensor Test (built in Self-Test) and manual Self-Test |
Operating current normal | 25 mA at 24 VDC |
Current in alarm, at 24 VDC | ±75 mA at 24 VDC |
Connections to: | – Fire control panels using end of line (EOL) and alarm resistors (current increase) – Devices that operate via relay switched outputs – PLCs with 4–20 mA inputs |
End of line and alarm resistor | To be adjusted to the fire control panel; free terminals are dedicated to the resistors Note: the alarm and EOL resistor must be rated 2 W min. each and the total power dissipation of both alarm and EOL resistor should not exceed 2 W |
Housing | Glass Reinforced Polyester (GRP), Non-incendive. UV resistant, Self-Extinguishing V–0 (UL-94) |
Swivel Mount | PA66, UV resistant; Stainless Steel fixings; 280 g (0.62 lb) |
Pressure compensating element | PCE (Pressure Compensating Element) avoids moisture build-up in the detector housing due to changes in ambient airpressure |
Dimensions | 4.9 x 3.15 x 2.25 in (125 x 80 x 57 mm) |
Weight | 1.05 lb (465 g) |
Ingress protection | IP65 |
Temperature, operating | –40 ˚F to +158 ˚F (–40 ˚C to +70 ˚C) |
Temperature, ambient ATEX and FM class 3611 | –13 ˚F to +158 ˚F (–25 ˚C to +70 ˚C) |
UV (Ultraviolet) Flame Detector |
|
---|---|
UVIR (Ultraviolet & Infrared) Flame Detector |
|
IR3 (3 Infrared bands) Flame Detector |
|
Accessories |
|
Honeywell FSL100 Series Flame Detectors
- UV, UV/IR and IR3 Flame Detectors to cover a wide range of applications
- Robust, simple to install & set up; Wide angle and fast speed of response
- Automatic test and test lamps for simple check and maintenance
Quantity: | Unit Price ($) |
1+ | Contact Us |
Quantity | Unit Price ($) |
1+ | Contact |
Product description
The Honeywell FSL100 Series Flame Detectors are Optoelectronic flame detectors for a wide range of Light Industrial fire detection from Honeywell Analytics.
Honeywell’s FSL100 range of Light Industrial/Commercial Flame Detectors enables simple coverage of fire hazard areas across many fire hazard applications. Installation, set-up and operation are simple. Wide solid area coverage and fast speed of response optimise safety. With inbuilt automatic test and test lamps available to cover all models, reliability is ensured.
A range of middle-market Optical Flame Detectors join the HA FSX High-End products. Addresses a wide range of fire protection applications both indoors and outdoors. With 3 versions to cover a wide range of flaming fires: Ultraviolet (UV), Ultraviolet/Infrared (UV/IR) and Triple Infrared (IR3).
Detecting a wide range of Hydrocarbon and Non-Hydrocarbon flaming fires means that many application areas can be addressed. Wide viewing angleOptical detection of radiant energy in a solid angle Field of View enables coverage of a large risk area. A simple optional mounting bracket allows the FSL100 to be installed and aligned covering the hazard. Fast responseFar faster than other technologies, by responding to flaming fires in seconds enabling a more rapid response to danger before the fire can escalate.
FM Class 1, 2 & 3 Div2 can be installed indoors or outdoors and in Hazardous areas typically looking into a Div 1 area from a distance.
FM 3260 performance certified to FM 3260 for flame Detector performance. Relay and current output (Fault and Alarm) Analog stepped output and Alarm/Fault relays for simple connectivity.
Inbuilt Automatic Test and Simple to use Test LampsFSL100 maintains continuous internal health monitoring. Test lamps enable simple operational and field-of-view testing.
Features & Benefits:
▪ UV, UV/IR and IR3 Flame Detectors to cover a wide range of applications
▪ Robust, simple to install & set up: Wide angle and fast speed of response
▪ Automatic test and test lamps for simple check and maintenance
Ease of Installation and Use:
▪ FSL100 Flame Detectors – UV, UV/IR and IR3 for light industrial applications
▪ GRP Housing, available in Red or White with optional swivel mount
▪ 12-14Vdc, 25mA nominal operation
▪ 4 to 20mA and Relay outputs
▪ Long range test lamp available
▪ High visibility red or discrete white models available
Great Performance:
▪ Approved to EN54-10 and FM3260 flame detector standards
▪ Comprehensive automatic self test
▪ Remote manual self test option
Fast & Reliable:
▪ High speed sensors and microprocessor
▪ Sophisticated analysis algorithms
▪ Continuous health monitoring
▪ False alarm rejection
Reduced Life Cost:
▪ Long life elements
▪ Pressure compensation to avoid contamination
▪ 2 year warranty
▪ Buy with confidence
Product Specification
General | |
---|---|
FSL100 Flame Detector types | FSL100-UV, FSL100-UVIR and FSL100-IR3; Choice of red or white housings |
Range | 110 ft /35 m (IR3), 25 m/80 ft (UV, UV/IR) alarming within 10 seconds to a 1 ft2(0.1 m2 )n-heptane fire |
Cone of vision | 90˚minimum horizontal and vertical |
Power | 10-28 VDC (12-24 VDC nominal) |
Local LEDs | – Continuous green: normal operation – Continuous yellow: fault – Flashing yellow: Fault and guide to repeat self-test after a self-test failure – Continuous red: alarm |
Current output | Standard available 4–20 mA (stepped, sinking, non-isolated): – 0 mA power fault / microprocessor fault – 2 mA optical fault – 4 mA normal operation – >20 mA alarm |
Relay output: – Alarm relay – Fault relay |
De-energized during normal operation, no alarm, SPDT, 30 VDC – 2 A, 60 W max. Energised during normal operation, no fault, SPDT, 30 VDC – 2 A, 60 W max. |
Cable gland & terminals | Cable entry M20 clearance. Supplied with gland suitable for cable diameter from 0.2” (5.5mm) to 0.5”(13mm). Terminals suitable for 0.5mm2 (20AWG) to 1.5mm2 (15AWG) wire |
Start up times | |
Alarm response time | 8 to 30 sec |
Alarm output settings | Selectable LEDs and relays latching/non-latching; factory setting: latching |
Automatic & manual Self-Test | Automatic Sensor Test (built in Self-Test) and manual Self-Test |
Operating current normal | 25 mA at 24 VDC |
Current in alarm, at 24 VDC | ±75 mA at 24 VDC |
Connections to: | – Fire control panels using end of line (EOL) and alarm resistors (current increase) – Devices that operate via relay switched outputs – PLCs with 4–20 mA inputs |
End of line and alarm resistor | To be adjusted to the fire control panel; free terminals are dedicated to the resistors Note: the alarm and EOL resistor must be rated 2 W min. each and the total power dissipation of both alarm and EOL resistor should not exceed 2 W |
Housing | Glass Reinforced Polyester (GRP), Non-incendive. UV resistant, Self-Extinguishing V–0 (UL-94) |
Swivel Mount | PA66, UV resistant; Stainless Steel fixings; 280 g (0.62 lb) |
Pressure compensating element | PCE (Pressure Compensating Element) avoids moisture build-up in the detector housing due to changes in ambient airpressure |
Dimensions | 4.9 x 3.15 x 2.25 in (125 x 80 x 57 mm) |
Weight | 1.05 lb (465 g) |
Ingress protection | IP65 |
Temperature, operating | –40 ˚F to +158 ˚F (–40 ˚C to +70 ˚C) |
Temperature, ambient ATEX and FM class 3611 | –13 ˚F to +158 ˚F (–25 ˚C to +70 ˚C) |
UV (Ultraviolet) Flame Detector |
|
---|---|
UVIR (Ultraviolet & Infrared) Flame Detector |
|
IR3 (3 Infrared bands) Flame Detector |
|
Accessories |
|