Honeywell Sensepoint High Temperature Combustible Gas Sensor
Description
- Low-cost disposable sensor
- Greater than 5 year typical operating life
- ATEX/ IECEx approved design
Product description
The Honeywell Sensepoint High Temperature (HT) Combustible Gas Sensor is a sealed disposable sensor for the detection of flammable gases.
The Sensepoint High Temperature (HT) Combustible Gas Sensor is a sealed disposable sensor for the detection of flammable gases. It must be fitted into a suitably approved Ex e or Ex d high-temperature junction box (e.g. FEEL Flameproof Enclosures) fitted with an approved cable gland for external wiring (e.g. Peppers Cable Glands, Series A3LF or CR3 CROLOCK Series).
The sensor features a filter housing that retains a stainless steel mesh filter. It employs a catalytic pellistor sensor device which is used as part of a bridge measuring circuit.
Sensepoint HT is certified for hazardous areas to EN60079 / EN61241 and is protected against water and dust ingress to IP66. The sensor is available in M20, M25 and 3/4 NPT thread versions.
Sensepoint Flammable – High Temperature (150?C with 3rd party performance approval) |
- 2106B2310 Sensepoint HT Flammable Sensor (ATEX) M20
- 2106B2311 Sensepoint HT Flammable Sensor (ATEX) M25
- 2106B2312 Sensepoint HT Flammable Sensor (ATEX) 3/4 NPT
- Note: For a complete sensor order correct number of FEEL Exe J.Box 2052D0001 and Weather Housing 00780-A-0076
|
Accessories |
- 00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm – 3 X 20mm Entries – ATEX Approved
- 2052D0001 High temperature Exe junction box. ATEX approved
- 00780-A-0160 Right Angle Mounting Bracket For Junction Box 00780-A-0100
- 02000-A-1635 Weatherproof cap for use with toxic detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
- 02000-A-1640 Weatherproof cap for use with combustible detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
- 00780-A-0076 Stainless steel weather housing for Sensepoint HT or 705 HT (for use with in high temperature applications or with duct mounting kits)
- 02000-A-1642 Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
- 02000-A-1645 Flow Housing Assembly (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
- 2106B2114 Sensepoint & Signalpoint Toxic Calibration Kit including calibration cover, removal tool, potentiometer adjustment tool
- 2106D2055 M36/M40 thread adaptor
- 225-262-138 Cable gland and caps, 20mm, Nylon
- 94000-C-1001 2″ Pipe Mount Plate (please separately order 90083-A-8034)
- 90083-A-8034 2 x 2″ U-Bolts x M6 C/W Nuts and Washers 316SS for 2″ Pipe Mount Plate
- 90053-A-7001 1-way Sensepoint M20 Duct Mount Kit. Please order separately 00780-A-0100, 02000-A-1640 (for Combustible versions) or 02000-A-1635 (for Toxic versions)
- 90053-A-7041 1-way Sensepoint M20 Duct Mount Kit ‘High Temp’. Please order separately
- 2052D0001 and 00780-A-0076
- 90053-A-8002 1-way Sensepoint M25 Duct Mount Kit. Please order separately 00780-A-0100, 02000-A-1640 (for Combustible versions) or 02000-A-1635 (for Toxic versions)
- 90068-A-8204 Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector toGas Bottle
- 90068-C-8291 PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter
- 90068-C-8292 Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter
- 00910-A-0404 Hydrophobic barrier assembly for Weather Housing
|
Spares |
- 2106B1545 O2 Electrochemical Cell Exch Kit
- 2106B1546 SO2 Electrochemical Cell Exchange Kit
- 2106B1547 Cl2 Electrochemical Cell Exch Kit
- 2106B1548 CO Electrochemical Cell Exch Kit
- 2106B1549 H2S Electrochemical Cell Exch Kit
- 2106B1593 NH3 0-100 ppm Electrochemical Cell Exchange Kit
- 2106B1594 NO Electrochemical Cell Exchange Kit
- 2106B1595 NH3 0-1000 ppm Electrochemical Cell Exch Kit
- 2106B1596 NH3 0-50 ppm Electrochemical Cell Exch kit
- 2106B1597 H2 0-1000 ppm Electrochemical Cell Exchange Kit
- 2106B1598 H2 10000 ppm Electrochemical Exchange Kit
- 2106B1599 NO2 0-10 ppm Electrochemical Exchange Kit
|
Honeywell Sensepoint High Temperature Combustible Gas Sensor
Mô tả
- Low-cost disposable sensor
- Greater than 5 year typical operating life
- ATEX/ IECEx approved design
Quantity | Unit Price ($) |
1+ | Contact |
The Honeywell Sensepoint High Temperature (HT) Combustible Gas Sensor is a sealed disposable sensor for the detection of flammable gases.
The Sensepoint High Temperature (HT) Combustible Gas Sensor is a sealed disposable sensor for the detection of flammable gases. It must be fitted into a suitably approved Ex e or Ex d high-temperature junction box (e.g. FEEL Flameproof Enclosures) fitted with an approved cable gland for external wiring (e.g. Peppers Cable Glands, Series A3LF or CR3 CROLOCK Series).
The sensor features a filter housing that retains a stainless steel mesh filter. It employs a catalytic pellistor sensor device which is used as part of a bridge measuring circuit.
Sensepoint HT is certified for hazardous areas to EN60079 / EN61241 and is protected against water and dust ingress to IP66. The sensor is available in M20, M25 and 3/4 NPT thread versions.
Sensepoint Flammable – High Temperature (150?C with 3rd party performance approval) |
- 2106B2310 Sensepoint HT Flammable Sensor (ATEX) M20
- 2106B2311 Sensepoint HT Flammable Sensor (ATEX) M25
- 2106B2312 Sensepoint HT Flammable Sensor (ATEX) 3/4 NPT
- Note: For a complete sensor order correct number of FEEL Exe J.Box 2052D0001 and Weather Housing 00780-A-0076
|
Accessories |
- 00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm – 3 X 20mm Entries – ATEX Approved
- 2052D0001 High temperature Exe junction box. ATEX approved
- 00780-A-0160 Right Angle Mounting Bracket For Junction Box 00780-A-0100
- 02000-A-1635 Weatherproof cap for use with toxic detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
- 02000-A-1640 Weatherproof cap for use with combustible detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
- 00780-A-0076 Stainless steel weather housing for Sensepoint HT or 705 HT (for use with in high temperature applications or with duct mounting kits)
- 02000-A-1642 Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
- 02000-A-1645 Flow Housing Assembly (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
- 2106B2114 Sensepoint & Signalpoint Toxic Calibration Kit including calibration cover, removal tool, potentiometer adjustment tool
- 2106D2055 M36/M40 thread adaptor
- 225-262-138 Cable gland and caps, 20mm, Nylon
- 94000-C-1001 2″ Pipe Mount Plate (please separately order 90083-A-8034)
- 90083-A-8034 2 x 2″ U-Bolts x M6 C/W Nuts and Washers 316SS for 2″ Pipe Mount Plate
- 90053-A-7001 1-way Sensepoint M20 Duct Mount Kit. Please order separately 00780-A-0100, 02000-A-1640 (for Combustible versions) or 02000-A-1635 (for Toxic versions)
- 90053-A-7041 1-way Sensepoint M20 Duct Mount Kit ‘High Temp’. Please order separately
- 2052D0001 and 00780-A-0076
- 90053-A-8002 1-way Sensepoint M25 Duct Mount Kit. Please order separately 00780-A-0100, 02000-A-1640 (for Combustible versions) or 02000-A-1635 (for Toxic versions)
- 90068-A-8204 Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector toGas Bottle
- 90068-C-8291 PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter
- 90068-C-8292 Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter
- 00910-A-0404 Hydrophobic barrier assembly for Weather Housing
|
Spares |
- 2106B1545 O2 Electrochemical Cell Exch Kit
- 2106B1546 SO2 Electrochemical Cell Exchange Kit
- 2106B1547 Cl2 Electrochemical Cell Exch Kit
- 2106B1548 CO Electrochemical Cell Exch Kit
- 2106B1549 H2S Electrochemical Cell Exch Kit
- 2106B1593 NH3 0-100 ppm Electrochemical Cell Exchange Kit
- 2106B1594 NO Electrochemical Cell Exchange Kit
- 2106B1595 NH3 0-1000 ppm Electrochemical Cell Exch Kit
- 2106B1596 NH3 0-50 ppm Electrochemical Cell Exch kit
- 2106B1597 H2 0-1000 ppm Electrochemical Cell Exchange Kit
- 2106B1598 H2 10000 ppm Electrochemical Exchange Kit
- 2106B1599 NO2 0-10 ppm Electrochemical Exchange Kit
|